System Structure |
 |
Power Supply Section |
Output Frequency
|
25kHz to 100kHz, Accuracy : ±1% of set value
0.1kHz step variable, sine wave |
External Signal Input*
|
25kHz to 100kHz, sine wave
|
Output Voltage |
As-114 B : 3kVrms(high on one end), 3kVrms(high on both ends)
|
As-128 : 4kVrms(high on one end), 4kVrms(high on both ends)
|
As-130 : 4kVrms(high on one end), 6kVrms(high on both ends)
|
Output Current |
20mArms |
Output Voltage
Distortion Factor
|
Within 5% (25kHz to 100kHz)
|
CV Mode |
Constant voltage mode that controls the output voltage Vo at a constant value.
|
CC Mode
|
Constant current mode that controls the lamp current I at a constant value. |
Vds Mode |
The mode that measures the lighting start voltage and discharge time log. |
 |
|
 |
Voltage Measurement Section (Vo, V ) |
AC Monitor
Output |
Gain |
1/1000 |
Accuracy |
±3% of the full scale*1 |
Indicator |
Display Range
|
As-114B : 0 to 3000Vrms, 0 to 9999Vp-p
As-128: 0 to 4000Vrms, 0 to 9999Vp-p As-130: 0 to 6000Vrms, 0 to 9999Vp-p
|
Accuracy |
±3% of the full scale |
|
 |
Current Measurement Section (I ) |
AC Monitor
Output |
Gain |
1Vrms/10mArms
|
Accuracy |
±3% of the full scale |
Indicator |
Display Range
|
0 to 20.00mArms
|
Accuracy |
±3% of the 20mArms |
|
 |
CCFL Test Bench |
Acceptable Lamp*2
Dimension
|
As-114B : 50mm to 1200mm
As-128: 50mm to 1500mm As-130: 50mm to 1500mm
|
External Inverter
Connection |
Voltage and current can be measured by using an
external inverter. |
|
 |
General Items |
Power Supply
|
AC 100V(AC110V, 200V or 220V is available) ±10%,
48Hz to 62Hz
|
Power Consumption |
As-114B : 600VA or lower, As-128 : 800VA or lower, As-130: 1000VA or lower
|
Operating
Temperature/
Humidity
|
Main Unit
|
0 to +40ºC, 10 to 85% RH |
CCFL Test
Bench |
-25ºC*3 to +105ºC, 0 to 95% RH
Maximum wet bulb temperature: 38ºC
|
GPIB Interface
|
Reads Vo, VR , and I values,
Switches among CV, CC, and Vds modes,
Switches V rms/p-p, turns on/off high voltage output
|
Shock Guard Function
|
The high voltage output is cut off when the CCFL test
bench cover is opened. |
Withstand Voltage |
Between power input pairs and others: AC 1500V,
1 minute
|
Insulating Resistance |
Between power input pairs and others: 50Mω or
higher at DC 500V |
|
*1 : The full scale value : 3Vrms with As-114B, 4Vrms with As-128, 6Vrms with As-130.
The output voltage is calibrated with our High voltage divider.
*2 : CCFL test bench can be manufactured according to customer's request of CCFL's length and shape.